Normal reference values of d-dimer clinical pathology unit htmc 2023.
Keywords:
Clinical Pathology, Reference Values, D-Dimer, Clinical and Laboratory Standards Institute (CLSI).Abstract
Taking into consideration that it is a permanent practice of laboratories to take the reference values from the inserts of commercial houses and that this undoubtedly results in erroneous reference values for the work of the medical team, taking into consideration that biological variables such as race, genetics, culture, lifestyle, climate, temperature, even socioeconomic components of the populations influence their values. A prospective, quantitative cross-sectional study was carried out in the Clinical Pathology Unit of the Teodoro Maldonado Carbo Specialty Hospital, processing the samples in the INMULITE equipment after all the quality control processes were carried out, the sample was extracted. in blood donors and health professionals of the HTMC, after applying inclusion and exclusion criteria to the Universe and sample that consisted of 183 patients, applying the standards for the study of biological fluids of the Clinical and Laboratory Standards Institute (CLSI), it was They obtain reference values that range from 0 to 380 mg/dl.
Downloads
References
- Flores, C. F. Y., Pineda, Á. D. L. M. H., Paredes, F. X. P., & Veloz, Á. P. M. (2023). Importancia del laboratorio clínico en el diagnóstico del cáncer de pulmón. Revista Sanitaria de Investigación, 4(2), 91
- Peña Tumay, A. E. (2019). Validación para la transferencia de los intervalos de referencia de la citometría hemática establecidos por la OMS a la población de hombres y mujeres de entre 20 a 40 años, atendidos en un laboratorio privado, siguiendo el protocolo de la guía EP28-A3C del CLSI, Lima, 2018.
- Hernández, Á. G. (Ed.). (2019). Principios de bioquímica clínica y patología molecular. Elsevier Health Sciences. Página 29.
- Rubio Arce, N. S., & Pepper Zamora, J. E. (2019). Identificación de rangos referenciales de parathormona en laboratorio clínico y su utilidad en la seguridad de la paciente propuesta: establecer rango de referencias pruebas de laboratorio como aporte para un correcto diagnóstico, tratamiento y seguimiento de la salud de los usuarios (Doctoral dissertation, Universidad de Guayaquil. Facultad de Ciencias Médicas. Carrera de Tecnología Médica).
-Llor Zaragoza, P. Validez y seguridad del dímero D y la escala de Wells para el diagnóstico de sospecha de Tromboembolismo pulmonar y trombosis venosa profunda.
-Sánchez Tubón, W. S. (2019). Evaluación de factores patológicos y no patológicos que alteran valores de Hemoglobina Glucosilada (HbA1c) consulta externa Hospital FF. AA N° 1 (Enero-Abril 2018) (Bachelor's thesis, Quito: UCE).
-Reyes Suárez, J. J. (2018). Intervalos de referencia biológicos para colesterol, HDL colesterol y LDL colesterol en población adulta joven. Laboratorio José Darío Moral. Guayaquil-Ecuador. 2017-2018 (Bachelor's thesis, Universidad de Guayaquil. Facultad de Ciencias Químicas).
- Boza Sulca, L. W. (2019). Determinación de intervalos de referencia de los índices eritrocitarios en donantes-Hospital Nacional Hipólito Unanue 2018.
-Pilco Chimbo, M. A., & Sashqui Guaypacha, G. A. (2018). Determinación de transaminasas como aporte para el establecimiento de valores de referencia en estudiantes de unidades educativas rurales del Cantón Riobamba (Bachelor's thesis, Riobamba, Universidad Nacional de Chimborazo, 2018).
- Boza Sulca, L. W. (2019). Determinación de intervalos de referencia de los índices eritrocitarios en donantes-Hospital Nacional Hipólito Unanue 2018.
Ballez Rojas, G. S. (2018). Intervalos de referencia en pruebas de Coagulación en donantes sanos del inen–lima 2016.
-Duboscq, C., Ceresetto, J. M., Martinuzzo, M., Bottaro, F., Ramos, G., Echenagucia, M., ... & Sua, L. F. (2018). Uso y limitaciones del dímero D en la exclusión del tromboembolismo venoso. Revista Hematología, 22(1), 55-65.
-Fernanda Lilian, P. B. (2021). Influencia de la variabilidad biológica en los resultados de la citometría hemática (Bachelor's thesis, Universidad Nacional de Chimborazo).
- Díaz Padilla, D., & Santoyo Pérez, M. (2019). El Laboratorio Clínico en la mejoría continúa de la calidad. Revista de Ciencias Médicas de Pinar del Río, 23(3), 357-359.
- Altamirano Almendariz, D. E., & Oleas Vizuete, T. E. (2018). Determinación de hormonas tiroideas como aporte para el establecimiento de valores de referencia en estudiantes de unidades educativas rurales del cantón Riobamba (Bachelor's thesis, Riobamba, Universidad Nacional de Chimborazo).
-Hilderink, J. M., van der Linden, N., Kimenai, D. M., Litjens, E. J., Klinkenberg, L. J., Aref, B. M., ... & Meex, S. J. (2018). Variación biológica de Creatinina, Cistatina C y Tasa de Filtrado Glomerular Estimada a lo largo de 24 horas. Acta bioquímica clínica latinoamericana, 52(4), 489-500.
-Morales Chasipanta, J. M. (2016). Determinación de valores de referencia para reticulocitos tomando como muestra representativa pacientes que acudieron al Laboratorio Clínico del Hospital de Especialidades Eugenio Espejo durante el periodo enero-julio 2018.
-Reyes Hernández, D. (2020). Uso de los valores de referencia de la función pulmonar. Revista Cubana de Medicina Militar, 49(4).
- Yoll-Guilarte, L., & Acosta-García, E. (2022). Verificación y transferencia de intervalos de referencia de variables bioquímicas de rutina. Medicina y Laboratorio, 26(4), 365-374..
- Palomino Astupiña, J. (2018). Interpretacion de valores de referencia en pruebas bioquímicas, INEN 2016.
-Rojas Quispe, M. V. (2019). Valores de referencia de perfil hepático y lipídico en personas que viven a 3000 metros sobre el nivel del mar (Bachelor's thesis, Universidad Técnica de Ambato-Facultad de Ciencias de la Salud-Carrera de Laboratorio Clínico).
-Castro, S. G., Calle, C. R., Palomares, L. J., Huguet, E. T., Mayen, A. T., Franquiz, W. B., ... & Castro, D. J. (2022). Adjusted D-dimer cutoff levels to rule out pulmonary embolism in patients hospitalized for COPD exacerbation: results from de SLICE trial.
-Bellesini, M., Robert‐Ebadi, H., Combescure, C., Dedionigi, C., Le Gal, G., & Righini, M. (2021). D‐dimer to rule out venous thromboembolism during pregnancy: a systematic review and meta‐analysis. Journal of Thrombosis and Haemostasis, 19(10), 2454-2467.
-Remache Tipán, A. L. (2018). Determinación de la variabilidad biológica intra e interindividual de los biomarcadores sanguíneos, en los pacientes con enfermedad renal crónica estadio 5, en hemodiálisis, del CMFIEDM, aplicando la metodología de química seca (Bachelor's thesis, Quito: UCE).
-Azua, K. A. B., Rodríguez, Á. A. A., & Villacreses, W. A. L. (2023). Normas ISO 15189 y la calidad integral en los laboratorios clínicos. MQRInvestigar, 7(1), 935-955.
- http://www.lapropharmplus.com/site/asset/images/pdf/815bf6daf173af58c21d38621b7fd069.pdf
Downloads
Published
How to Cite
Issue
Section
License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The authors retain the rights to the articles and are therefore free to share, copy, distribute, perform and publicly communicate the work on their personal websites or in institutional repositories, after publication in this journal, as long as they provide information bibliography that certifies its publication in this journal.
The works are under one